Adrenaline (Epinephrine) Infusion
Syringe pump continuous infusion preparation (80 mcg/mL), hemodynamic titration, and extravasation surveillance protocol.
Syringe Pump Infusion Preparation (Standard Concentration)
| Ampoule Presentation | 1 mL ampoule, 1 mg/mL of adrenaline (1:1,000 solution) |
|---|---|
| Adrenaline Dose | 4 mg (4 mL of 1:1,000) |
| Compatible Diluent | 46 mL of 0.9% Sodium Chloride or D5W |
| Final Syringe Volume | 50 mL |
| Final Concentration | 80 mcg/mL |
| Stability | 24 hours at room temperature |
Materials Required
- Adrenaline ampoules 1 mg/mL × 4
- 60 mL Luer-lock syringe
- 0.9% Sodium Chloride (NS) or 5% Dextrose (D5W)
- Sterile drawing-up / filter needle
- Dedicated syringe pump infusion label
- Extension line (100 cm)
- Alcohol chlorhexidine swabs
Preparation Procedure (Aseptic Non-Touch Technique)
- Verification: Verify the written physician order, patient identity, body weight, and clinical indication.
- Hand Hygiene: Perform thorough hand hygiene and clean preparation workspace.
- Ampoule Check: Inspect all 4 adrenaline ampoules for:
- Correct drug and strength, adrenaline (1 mg/mL = 1:1,000)
- Expiry date
- Container integrity, clarity, and absence of precipitate or discoloration
- Withdrawal: Draw up exactly 1 mL from each of the 4 ampoules into a 60 mL Luer-lock syringe (Total: 4 mL = 4 mg).
- Dilution: Add 46 mL of 0.9% Normal Saline or 5% Dextrose to achieve a final volume of 50 mL.
- Mixing: Gently invert the syringe several times to ensure homogenous mixing.
- Visual Inspection: Inspect solution to ensure it is clear, colorless, and free of visible particles.
- Labeling & Dual Verification: Apply infusion label and obtain an independent double-check by another registered nurse.
- Syringe Pump Setup: Prime the extension set, install into the syringe pump, and shield from excessive ambient light.
🔒 Lumen Policy: Adrenaline is physically and chemically incompatible with numerous medications. It must be infused via a dedicated central venous catheter lumen whenever possible.
⚠️ Peripheral Administration: If central venous access is not yet established, infusion may be delivered via a large peripheral vein for short-term bridging only, with continuous extravasation monitoring.
Administration & Titration
Recommended Dosing Parameters
- Administration Route: Administer via syringe pump; dedicated central line lumen preferred.
- Recommended Starting Dose: 0.01 to 0.05 mcg/kg/min (titrate infusion to achieve desired hemodynamic result).
- Typical ICU Titration Range: 0.01 to 0.5 mcg/kg/min.
- High-Dose Range: Higher doses may be used depending on clinical condition under direct intensivist supervision.
- Syringe Continuity: Do not allow the infusion to run out. A syringe can be made up to a maximum of 1 hour in advance and labelled clearly with contents and expiry.
- Discard Policy: Discard 24 hours after preparation or earlier if the solution becomes discoloured, cloudy, or contaminated.
Hemodynamic Monitoring Requirements
- Monitor arterial blood pressure continuously (invasive arterial line preferred).
- Monitor heart rate and continuous ECG rhythm for dysrhythmias or reflexive bradycardia.
- Monitor for peripheral tissue ischemia or necrosis.
- Assess end-organ perfusion markers (urine output, mental status, peripheral pulse volume, serum lactate).
Extravasation Surveillance & Response Protocol
Peripheral vasopressor extravasation causes profound α1-mediated cutaneous vasoconstriction, which can lead to ischemic necrosis and gangrene.
Normal Infusion Site
- No cutaneous blanching
- No local swelling
- No pain, burning, or stinging
- No tissue discolouration
Extravasation Suspected:
- STOP infusion immediately (do not flush line).
- Notify clinician promptly.
- Aspirate residual drug through the cannula if possible, then remove catheter.
- Document event in patient clinical record.
Adrenaline Infusion Rate Chart (80 mcg/mL)
Shows equivalent dose in mcg/kg/min for a given pump rate (mL/hr) across patient weights. Central venous line administration preferred.
| Pump Rate (mL/hr) |
Patient Weight (kg) & Calculated Dose (mcg/kg/min) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 40 kg | 45 kg | 50 kg | 55 kg | 60 kg | 65 kg | 70 kg | 75 kg | 80 kg | 85 kg | 90 kg | 95 kg | 100 kg | |
| 1 mL/hr | 0.03 | 0.03 | 0.03 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.01 | 0.01 | 0.01 |
| 2 mL/hr | 0.07 | 0.06 | 0.05 | 0.05 | 0.04 | 0.04 | 0.04 | 0.04 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 |
| 3 mL/hr | 0.10 | 0.09 | 0.08 | 0.07 | 0.07 | 0.06 | 0.06 | 0.05 | 0.05 | 0.05 | 0.04 | 0.04 | 0.04 |
| 4 mL/hr | 0.13 | 0.12 | 0.11 | 0.10 | 0.09 | 0.08 | 0.08 | 0.07 | 0.07 | 0.06 | 0.06 | 0.06 | 0.05 |
| 5 mL/hr | 0.17 | 0.15 | 0.13 | 0.12 | 0.11 | 0.10 | 0.10 | 0.09 | 0.08 | 0.08 | 0.07 | 0.07 | 0.07 |
| 6 mL/hr | 0.20 | 0.18 | 0.16 | 0.15 | 0.13 | 0.12 | 0.11 | 0.11 | 0.10 | 0.09 | 0.09 | 0.08 | 0.08 |
| 7 mL/hr | 0.23 | 0.21 | 0.19 | 0.17 | 0.16 | 0.14 | 0.13 | 0.12 | 0.12 | 0.11 | 0.10 | 0.10 | 0.09 |
| 8 mL/hr | 0.27 | 0.24 | 0.21 | 0.19 | 0.18 | 0.16 | 0.15 | 0.14 | 0.13 | 0.13 | 0.12 | 0.11 | 0.11 |
| 9 mL/hr | 0.30 | 0.27 | 0.24 | 0.22 | 0.20 | 0.18 | 0.17 | 0.16 | 0.15 | 0.14 | 0.13 | 0.13 | 0.12 |
| 10 mL/hr | 0.33 | 0.30 | 0.27 | 0.24 | 0.22 | 0.21 | 0.19 | 0.18 | 0.17 | 0.16 | 0.15 | 0.14 | 0.13 |
| 11 mL/hr | 0.37 | 0.33 | 0.29 | 0.27 | 0.24 | 0.23 | 0.21 | 0.20 | 0.18 | 0.17 | 0.16 | 0.15 | 0.15 |
| 12 mL/hr | 0.40 | 0.36 | 0.32 | 0.29 | 0.27 | 0.25 | 0.23 | 0.21 | 0.20 | 0.19 | 0.18 | 0.17 | 0.16 |
| 13 mL/hr | 0.43 | 0.39 | 0.35 | 0.32 | 0.29 | 0.27 | 0.25 | 0.23 | 0.22 | 0.20 | 0.19 | 0.18 | 0.17 |
| 14 mL/hr | 0.47 | 0.41 | 0.37 | 0.34 | 0.31 | 0.29 | 0.27 | 0.25 | 0.23 | 0.22 | 0.21 | 0.20 | 0.19 |
| 15 mL/hr | 0.50 | 0.44 | 0.40 | 0.36 | 0.33 | 0.31 | 0.29 | 0.27 | 0.25 | 0.24 | 0.22 | 0.21 | 0.20 |
| 16 mL/hr | 0.53 | 0.47 | 0.43 | 0.39 | 0.36 | 0.33 | 0.30 | 0.28 | 0.27 | 0.25 | 0.24 | 0.22 | 0.21 |
| 17 mL/hr | 0.57 | 0.50 | 0.45 | 0.41 | 0.38 | 0.35 | 0.32 | 0.30 | 0.28 | 0.27 | 0.25 | 0.24 | 0.23 |
| 18 mL/hr | 0.60 | 0.53 | 0.48 | 0.44 | 0.40 | 0.37 | 0.34 | 0.32 | 0.30 | 0.28 | 0.27 | 0.25 | 0.24 |
| 19 mL/hr | 0.63 | 0.56 | 0.51 | 0.46 | 0.42 | 0.39 | 0.36 | 0.34 | 0.32 | 0.30 | 0.28 | 0.27 | 0.25 |
| 20 mL/hr | 0.67 | 0.59 | 0.53 | 0.48 | 0.44 | 0.41 | 0.38 | 0.36 | 0.33 | 0.31 | 0.30 | 0.28 | 0.27 |
Pharmacokinetic Infusion Conversion Formulae
Standard equations for an 80 mcg/mL solution (4 mg in 50 mL):
Rate (mL/hr) = [ Dose (mcg/kg/min) × Weight (kg) × 60 ] / 80
Dose (mcg/kg/min) = [ Rate (mL/hr) × 80 ] / [ Weight (kg) × 60 ]